National Deviation
Clause RequirementTest Result - Remark Verdict
Australia National Differences according to CB Bulletin No. 107A, May 2004
20.2.3 After this Clause, add the following variation:
20.201 Resistance to fire - Alternative tests
20.201.1 General
Parts of non-metallic material shall be resistant to
ignition and the spread of fire.
This requirement does not apply to decorative
trims, knobs and other parts unlikely to be ignited
or to propagate flames originating from inside the
apparatus, or the following:
(a) Components that are contained in an
enclosure having a flammability category
of V-0 according to AS/NZS 60695.11.10
and having openings only for the
connecting wires filling the openings
completely, and for ventilation not
exceeding 1 mm in width regardless of
length.
(b) The following parts which would contribute
negligible fuel to a fire:
-
small mechanical parts, the mass of
which does not exceed 4g, such as
mounting parts, gears, cams, belts
and bearings;
-
small electrical components, such as
capacitors with a volume not
exceeding 1750mm
3
, integrated
circuits, transistors and optocoupler
packages, if these components are
mounted on material of flammability
category V-1 or better according to
AS/NZS 60695.11.10
Equipment under test and
materials used materials and
components in compliance
with requirements of
IEC 60065.
N