<11006749 001>
Page 32 of 50
10.3 TABLE: insulation resistance measurements
P
Insulation resistance R between: R (MΩ) Required R (MΩ)
Hazardous live and enclosure with metal foil 999 4
Hazardous live and accessible 999 4
Hazardous live and protective earth terminal 999 2
Hazardous live and tuner terminal 999 4
Note:
Performed with all types of tuner.
10.3 TABLE: electric strength measurements
P
Test voltage applied between: Test voltage (V) Breakdown
Hazardous live and accessible DC 4240 No
Hazardous live and enclosure with metal foil DC 4240 No
Hazardous live and protective earth terminal DC 2718 No
Hazardous live and tuner terminal
DC 4240 No
Note:
Performed with all types of tuner.
11.1 TABLE: Electric shock hazard under fault condition
P
measured between: U1 (V) required U1
(Vpk)
U2 (V) required U2
(Vpk)
For equipment equipped with AUO panel
Line – plastic enclosure *
)
-- -- -- --
Neutral – plastic enclosure *
)
-- -- -- --
Line – SELV (earthed) 0.16 35 0.04 0.35
Neutral – SELV (earthed) 0.15 35 0.04 0.35
Line – CN10 Hi 0.13 35 0.03 0.35
Neutral – CN10 Hi 0.13 35 0.03 0.35
Line – CN10 Lo 0.13 35 0.03 0.35
Neutral – CN10 Lo 0.13 35 0.03 0.35
Line – T8 Pin 10 *
)
-- -- -- --