4-19
SMOR
Building
The array is being built.
Created
The array or device is defined but not
initialized.
Dead
A write-back cache to the array command
failed. This is an unrecoverable failure.
Degraded
A single drive in the array has failed; array
performance is affected.
Impacted
A verification is being performed on the array;
I/O performance is affected.
Missing
A drive is physically missing or will not
respond to commands on the device bus.
Optimal
The array is fully functional.
Pending
The array has been created and the build is
queued on the controller, but is not yet
started.
Rebuilding
Data is being rebuilt onto a drive in the array.
Warning
This status indicates that a drive in a fault
tolerant array has failed and the next drive
failure will cause loss of the array.
Setting the Configuration
There are two configuration options on the File menu:
Read System Config Causes SMOR to rescan to detect any changes in
hardware configuration or status. Any changes
that have been made and not saved are lost. This
operation is run automatically when SMOR is
started.
Set System Config Causes SMOR to save changes that have been
made to the storage subsystem configuration in
the controller memory. If any array groups or
parity groups have been created or modified, this
operation causes the controller to initiate a build
operation on the new groups.