Adapter Configuration and Installation
Configuring Device IDs
The SCSI specification allows up to 7 SCSI devices (and a controller) to be
connected to a single 8-bit SCSI bus. A Wide SCSI bus can support up to 15
devices (and a controller). Up to 126 devices can be attached to a single
Fibre Channel loop.
SCSI
All SCSI devices, including the controller, must be assigned a unique SCSI
ID. SCSI IDs, which are typically set using jumpers or switches on
peripheral devices, can be assigned any number from 0 to 7 for 8-bit SCSI
devices or 0 to 15 for Wide SCSI devices. For more information on SCSI
IDs, see Chapter 7, Theory of Operation.
Set the SCSI ID of each SCSI device attached to the controller to a unique
ID number between 0 and 6. The SmartRAID V controller is set to ID 7 by
default (most SCSI controllers use ID 7.) Wide SCSI devices can also use
SCSI IDs 8 through 15. SCSI IDs can be duplicated on the same controller
if the devices using the same ID are not attached to the same bus.
If necessary, the SmartRAID controller ID can be changed to any ID 0 7
by using SMOR or from the Configure Host Bus Adapter window in
Storage Manager.
NOTE Changing the controller ID is not recommended. You should
leave the SmartRAID V controller at SCSI ID 7.
Fibre Channel
DPT Fibre Channel controllers and their attached Fibre Channel devices
are configured automatically during boot. Device IDs are assigned within
the range 0 126 and cannot be changed manually.